Gas Analysis solutions through advanced sensor and analyzer technology

 

General Purpose ppm Oxygen Analyzers

GPR-1600 MS Oxygen Analyzer

GPR-1600 MS ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb. Automated range, zero, calibration, data acquisition, system diagnostic functions. Optional: 3 solenoid inlet valves control the introduction sample, span, zero  gas to the analyzer enabling auto zero and calibration functions.
Panel mount configuration with optional bezel for 19” rack mounting.
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm
               Optional:    0-500 ppb, 0-5 ppm, 0-50 ppm, 0-500 ppm

 

GPR 1600 MS-W ppm Oxygen Analyzer

GPR-1600 MS-W ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb. Automated range, zero, calibration, data acquisition, system diagnostic functions. Optional: 3 solenoid inlet valves control the introduction sample, span, zero  gas to the analyzer enabling auto zero and calibration functions.
Wall mount NEMA 4 configuration.
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm
               Optional:    0-500 ppb, 0-5 ppm, 0-50 ppm, 0-500 ppm

 

GPR-1600 MS-T Oxygen Analyzer

GPR-1600 MS-T ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor and electronics platform with manual flow control valve and flow indicator. Panel mount configuration with optional bezel for 19” rack mounting. Optional: 3 solenoid inlet valves control the introduction sample, span, zero  gas to the analyzer enabling auto zero and calibration functions.
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm
               Optional:    0-500 ppb, 0-5 ppm, 0-50 ppm, 0-500 ppm

 

GPR-16 MS ppm Oxygen Analyzer

GPR-16 MS ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb. Manually operated bypass sample system isolates of the sensor from high oxygen levels. 19” rack or panel mount configuration
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm

 

 

GPR-16 MS-W ppm Oxygen Analyzer

GPR-16 MS-W ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb. Manually operated bypass sample system isolates of the sensor from high oxygen levels. 19” rack or panel mount configuration
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm

 


 

GPR-16 MS-W-306 ppm Oxygen Analyzer

GPR-16 MS-W-306 ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb. Manually operated bypass sample system isolates of the sensor from high oxygen levels. Wall mount NEMA 4 configuration.
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm

 


      

GPR-1600 ppm Oxygen Analyzer

GPR-1600 ppm Oxygen Analyzer
Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Automated range, zero, calibration, data acquisition, system diagnostic functions. Optional: 3 solenoid inlet valves control the introduction sample, span, zero  gas to the analyzer enabling auto zero and calibration functions. Panel mount configuration with optional bezel for 19” rack mounting.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-1600 W ppm Oxygen Analyzer

GPR-1600 W ppm Oxygen Analyzer
Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Automated range, zero, calibration, data acquisition, system diagnostic functions. Optional: 3 solenoid inlet valves control the introduction sample, span, zero  gas to the analyzer enabling auto zero and calibration functions. Wall mount NEMA 4 configuration.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%
               Optional:   0-5 ppm, 0-50 ppm, 0-500 ppm, 0-0.5%, 0-25%

 

GPR-1600 T ppm Oxygen Analyzer

GPR-1600 T ppm Oxygen Analyzer
Proprietary advanced galvanic sensor and electronics platform with manual flow control valve and flow indicator. Panel mount configuration with optional bezel for 19” rack mounting. Optional: 3 solenoid inlet valves control the introduction sample, span, zero  gas to the analyzer enabling auto zero and calibration functions.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-16 ppm Oxygen Analyzer

GPR-16 ppm Oxygen Analyzer
Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Manually operated bypass sample system isolates of the sensor from high oxygen levels. 19” rack or panel mount configuration
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-16 W ppm Oxygen Analyzer

GPR-16 W ppm Oxygen Analyzer
Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Manually operated bypass sample system isolates of the sensor from high oxygen levels. Wall mount NEMA 4 configuration.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-16 W-306 ppm Oxygen Analyzer

GPR-16 W-306 ppm Oxygen Analyzer
Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Manually operated bypass sample system isolates of the sensor from high oxygen levels. Wall mount NEMA 4 configuration.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-1900 MS ppm Oxygen Analyzer

GPR-1900 MS ppm Oxygen Analyzer
Proprietary MS Pico-Ion sensor capable of oxygen analysis under 10 ppb. Automated range, zero, calibration, data acquisition, system diagnostic functions. Panel mount configuration for integration into OEM systems.
Ranges - Standard:  0-1 ppm, 0-10 ppm, 0-100 ppm, 0-1000 ppm

 

 

GPR-1900 ppm Oxygen Analyzer

GPR-1900 ppm Oxygen Analyzer
Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Automated range, zero, calibration, data acquisition, system diagnostic functions. Panel mount configuration for OEM systems.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-1500a ppm Oxygen Transmitter

GPR-1500 ppm Oxygen Transmitter
Two wire loop powered 4-20mA signal output operates on 12-28VDC. Proprietary advanced galvanic sensor capable of oxygen analysis under 100 ppb. Automated range, zero, calibration, system diagnostic functions. Wall mount NEMA 4 configuration. Suitable for use in Class 1, Division 1, Groups A-D hazardous areas with optional intrinsic safety barriers.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

GPR-1500b D ppm Oxygen Transmitter

 

GPR-1500 D ppm Oxygen Transmitter
Two wire loop powered 4-20mA signal output operates on 12-28VDC. Proprietary advanced galvanic sensor designed for oxygen analysis above 2 ppm. Automated range, zero, calibration, system diagnostic functions. Wall mount NEMA 4 configuration. Suitable for use in Class 1, Division 1, Groups A-D hazardous areas with optional intrinsic safety barriers.
Ranges - Standard:  0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

GPR-1500 DA ppm Oxygen Transmitter

GPR-1500 DA ppm Oxygen Transmitter
Operates on 9-28VDC with 4-20mA signal output and two (2) field configurable alarms with relay contacts. Proprietary advanced galvanic sensor designed for oxygen analysis above 2 ppm. Automated range, zero, calibration, system diagnostic functions. Wall mount NEMA 4 configuration.
Ranges - Standard:  0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

GPR-1500 DGB ppm Oxygen Transmitter

 

GPR-1500 DGB ppm Oxygen Transmitter
Two wire loop powered 4-20mA signal output operates on 12-28VDC designed exclusively for glove box applications. Proprietary advanced galvanic sensor designed for oxygen analysis below 1 ppm. Automated range, zero, calibration, system diagnostic functions. In-situ configuration located sensor inside and electronics outside glove box, thereby, eliminating the need for sampling pumps and reducing the possibility of contamination.
Ranges - Standard:  0-10 ppm, 0-100 ppm, 0-1000 ppm, 0-1%, 0-25%

 

 

 