Application Guide - Air Separation
 Service
 Measurement
 Gas Stream
 Analyzer Options

Ultra high purity N2 (8 nines to 9 nines) produced cryogenically

<1 ppb to 10 ppb O2

N2, Ar, H2, He

GPR-1600 UHP

GPR-1600 UHP-B

GPR-1600 UHP-M

 

- Spot checking above

 

GPR-1200 MS

Low ppm purity N2 (6 nines to 7 nines) generated cryogenically and ceramic membrane process

 

10 ppb to 1 ppm O2

 

 

N2, Ar, H2, He

GPR-1600 UHP

GPR-1600 UHP-B

GPR-1600 MS

GPR-1600 MS-W

GPR-16 MS

GPR-16 MS-W

GPR-16 MS-W-306

 

- Spot checking above

 

GPR-1200 MS

ppm purity N2 (5 nines) generated cryogenically, ceramic membrane, pressure swing adsorption (PSA) skid and deoxo catalytic processes

 

0.1 ppm to 10 ppm O2

 

 

N2, Ar, H2, He

GPR-1600 MS

GPR-1600 MS-W

GPR-16 MS

GPR-16 MS-W

GPR-16 MS-W-306

GPR-1600

GPR-16

- Spot checking above

 

GPR-1200

GPR-1100

Low ppm purity H2 produced by: electrolysis, catalytic partial oxidation of hydrocarbons and by dissolving solid sodium chloride into mercury bath

0.1 ppm to 10 ppm O2

 

 

H2

GPR-1600 MS

GPR-1600 MS-W

GPR-16 MS

GPR-16 MS-W

GPR-16 MS-W-306

GPR-1600

GPR-16

- Spot checking above

 

GPR-1200

GPR-1100

ppm level N2 (4 nines) generated by pressure swing adsorption (PSA) skid and deoxo catalytic

<1000 ppm O2

 

Air

GPR-1600

GPR-16

GPR-1500

GPR-1500 D

GPR-1500 DA

- Spot checking above

 

GPR-1200

GPR-1100

Transport of ppm level N2 via pipelines and tanker trucks to end users

0.1 ppm to 10 ppm O2

 

N2, Ar, H2, He

GPR-1600

GPR-16

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

Gas cylinder certification: specialty mixes including welding gas

0.1 ppm to 1% ppm O2

 

Varies

GPR-1600

GPR-16

GPR-1500

GPR-1500 D

GPR-1500 DA

 

- Spot checking above

 

GPR-1200

GPR-1100

GPR-1000

Gas cylinder certification: specialty mixes including welding gas

1% to 95% O2

 

Varies

GPR-2600

GPR-2600 W

GPR-2500

GPR-2500 A

 

- Spot checking above

 

GPR-2000

GPR-2000 P

GPR-3000 AHC

N2 (3 nines) generated from a membrane process mounted on portable skid

0.1% to 5% O2

 

Air

GPR-2600

GPR-2600 W

GPR-2500

GPR-2500 A

GPR-2900

 

- Spot checking above

 

GPR-2000

GPR-2000 P

GPR-3000 AHC

Medical grade O2 generated cryogenically

> 99.5% O2

Ar

GPR-3100

- Spot checking above

 

GPR-35 MO

O2 product purity of air separation process

90-100% O2

Air

GPR-3100

 

- Spot checking above

 

GPR-35 MO

O2 generated by pressure/vacuum swing adsorption (PSA/VPSA) processes mounted on portable skids

50% to 95% O2

 

Air

GPR-3100

GPR-2500 MO

 

- Spot checking above

 

GPR-35 MO

Synthetic air blenders for hospital back-up

20.9% O2

O2

GPR-2500

GPR-2900

 

- Spot checking above

 

GPR-2000

GPR-2000 P

GPR-3000 AHC

 

O2 deficiency in control rooms

<20.0%, <19.5% O2

Air, N2

GPR-35

GPR-2500 S

O2 deficiency/excess conditions inside N2 / O2 generator containers mounted on skids

<19.5%, >23.5% O2

Air, N2, O2

GPR-35

Application Guide - Beverage
 Service
 Measurement
 Gas Stream
 Analyzer Options

Quality control of CO2 delivery tankers

0-10 ppm O2

CO2

GPR_1600-1XLT
GPR-1600

GPR-1500

GPR-1200

Quality control of CO2 cylinders used in beverage dispensing

0-10 ppm O2

CO2

GPR-1600

GPR-1500

GPR-1200

Head space monitoring of fermentors, brew tanks and storage tanks

0-10 ppm O2

CO2

GPR-1600

GPR-1500

GPR-1200

Carbonation in bottling process

0-1% O2

CO2

GPR-2600

GPR-2600 W

GPR-2500

Off-line fermentors

0-10 ppm O2

CO2

GPR-1600

GPR-1500

GPR-1200

Head space monitoring of fermentors, brew tanks and storage tanks

0-10 ppm O2

CO2

GPR-1600

GPR-1500

GPR-1200

Head space monitoring of wood barrels

0-10 ppm O2

CO2

GPR-1600

GPR-1500

GPR-1200

Oxygen deficiency

19.5% O2

CO2, air

GPR-35

GPR-3000 A

Application Guide - Electronics
 Service
 Measurement
 Gas Stream
 Analyzer Options

High ppb cryogenic N2 Purity for production furnances

10 ppb to 1 ppm O2

 

N2, Ar, H2, He

GPR-1600 MS

GPR-1600 MS-W

 

- Spot checking above

 

GPR-1200 MS

 

 

 

 

 

ppm purity cryogenic, ceramic membrane, pressure swing adsorption (PSA) skid and deoxo catalytic generated N2 (5 nines)

0-10 ppm O2

 

N2, Ar, H2, He

GPR-1600

GPR-1600 W

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

ppm purity of furnace fuel gas for sintering ceramic powders into shapes

10 ppm to 1% O2

 

 

0.5% to 100% O2

 

Fuel gas

GPR-1600

GPR-1500

GPR-1900

GPR-2600

GPR-2500

GPR-2900

 

- Spot checking above

 

GPR-1200

GPR-1100

GPR-2000

 

 

 

 

O2 contamination in controlled atmospheres used for various sealing, firing and soldering processes to join dissimilar materials

0-10 ppm O2

 

N2

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

O2 contamination in N2 gases used in inert reflow soldering and wave soldering

0-10 ppm O2

 

N2

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

O2 contamination in N2, H2 gases used in the packaging of integrated circuits

0-10 ppm O2

 

N2

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

O2 deficiency in confined areas

<19.5-20.0% O2

Air, N2

GPR-35

 
Application Guide - Fiber Optics
 Service
 Measurement
 Gas Stream
 Analyzer Options

O2 impurity in inking process

0-10 ppm O2

N2

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

 
Application Guide - Glass
 Service
 Measurement
 Gas Stream
 Analyzer Options

Pure O2 generated cryogenically, pressure swing adsorption (PSA) and vacuum pressure swing adsorption (VPSA) processes mounted on skids replaces air to enrich existing processes and boost product yield and reduce NOx emissions

30% to 100% O2

 

 

 

Varies

GPR-3100

GPR-2500 MO

GPR-2600

GPR-2600 W

GPR-2900

 

 

- Spot checking above

 

GPR-35MO

GPR-2000

 
Application Guide - Glove Box Research & Manufacturing
 Service
 Measurement
 Gas Stream
 Analyzer Options

Leak tight environment to perform work with contamination sensitive or hazardous materials under an inert environment.

0-10 ppm O2

N2, Ar

GPR-1600 MS

GPR-1900MS

GPR-1600

GPR-1900

GPR-1500 DGB

 

 

 

 

Glove box controlled atmospheres for:

- Lithium battery research and production

- Crystal mounting

- Tissue study

- Assembly inspection

- Wire bonding

- Micro laser welding

- Semiconductor probing

- Thin film deposition

- Inkjet deposition

- Spin coating air sensitive materials

0-10 ppm O2

N2, Ar

GPR-1600 MS

GPR-1900MS

GPR-1600

GPR-1900

GPR-1500 DGB

 

 

 
Application Guide - Metals Processing
 Service
 Measurement
 Gas Stream
 Analyzer Options

ppm purity of furnace fuel gas for sintering metal powders into shapes and desired strength

<1 ppm O2

 

 

 

N2, H2

GPR-1600 MS

GPR-1600 MS-W

GPR-19MS 

GPR-1600

GPR-1600 W

GPR-1900

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Pure O2 generated cryogenically, pressure swing adsorption (PSA) and vacuum pressure swing adsorption (VPSA) processes mounted on skids replaces air to enrich existing processes and boost product yield and reduce NOx emissions

- zinc recovery processes

- gold leaching processes

- various brazing processes

- processing scrap aluminum

- improve heat transfer in electric-arc steel

  making furnaces

30% to 100% O2

 

Spot checking

Varies

GPR-3100

GPR-2500 MO

GPR-2600

GPR-2600 W

GPR-2900

 

 

- Spot checking above

 

GPR-35MO

GPR-2000

 

 

 

 

Low ppm purity H2 for heat treating and annealing finishing processe to produce desired hardness and brightness

0-10 ppm O2

 

H2, N2

GPR-1600

GPR-1600 W

GPR-1500

 

 

 

 

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Monitor oxygen contamiation in inert reducing furnaces for:

- Brazing

- Metallizing

- Annealing

- Degassing

0-10 ppm O2

 

H2, N2

GPR-1600

GPR-1600 W

GPR-1500

 
Application Guide - Natural Gas
 Service
 Measurement
 Gas Stream
 Analyzer Options

Continuous analysis of  vacuum extraction techniques create the possibility of O2 contamination that exceed contractual limits

5-20 ppm O2

 

 

CH4, CO2, H2S

 

H2S Sample System required

GPR-1500 AIS

GPR-1500 (barriers)

GPR-15 AXP

GPR-15 XP

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Protection of field personnel, gathering equipment, compressors and booster stations from the possible explosive hazard

0-10 ppm O2

 

 

CH4, CO2, H2S

 

H2S Sample System required

GPR-1500 AIS

GPR-1500 (barriers)

GPR-15 AXP

GPR-15 XP

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Cost effective monitoring of producers to identify those with O2 contamination levels that exceed contractual limits

0-100 ppm O2

 

 

CH4, CO2, H2S

 

H2S Sample System required

GPR-15 AXP

GPR-15 XP

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Corrosion in gathering lines (air, H2O, H2S react to form sulfuric acid

0-100 ppm O2

CH4, CO2, H2S

GPR-1200

GPR-1100

 

 

 

 

Protection of catalyst and regeneration beds

0-10 ppm O2

 

 

CH4, CO2, H2S

 

H2S Sample System required

GPR-1500 AIS

GPR-1500 (barriers)

GPR-15 AXP

GPR-15 XP

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Processing of ‘cleaned’ natural gas

0-10 ppm O2

 

 

CH4, CO2, H2S

 

H2S Sample System required

GPR-1500 AIS

GPR-1500 (barriers)

GPR-15 AXP

GPR-15 XP

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Protecting welds from atmospheric (oxygen) contamination by purging the area immediately around the weld with inert gases is essential to enhancing quality and reducing costs. Common problems include coking, oxidation and discoloration during TIG welding process, titanium fabrication and welding of stainless steel pipes, tubes and tanks.

10 ppm to 20.9%

N2, Ar

GPR-1100

GPR-1000

GPR-3000 AHC

 

 

 

 

Gas cylinder certification: specialty mixes including welding gas

0.1 ppm to 1% ppm O2

 

Varies

GPR-1600

GPR-16

GPR-1500

GPR-1500 D

GPR-1500 DA

 
Application Guide - Ozone Generation
 Service
 Measurement
 Gas Stream
 Analyzer Options

Pressure swing adsorption (PSA) and vacuum pressure swing adsorption (VPSA) skid generated O2

50% to 95% O2

 

Air

GPR-3100

GPR-3100 W

GPR-2500 MO

GPR-2600

GPR-2600 W

GPR-2900

 

- Spot checking above

 

GPR-35MO

GPR-2000

 
Application Guide - Petrochemical
 Service
 Measurement
 Gas Stream
 Analyzer Options

Low ppm level O2 contamination can act as a catalyst of undesirable polymerization during steam cracking hydrocarbon feedstocks (ethane, propane, butane, naptha, natural gas, etc.) to produce olefin feedstocks (ethylene, propylene, butadiene, H2 and others) that are then separated and purified; and, increasing O2 levels indicate an air leak creating a potentially explosive hazard

250 ppb to 5 ppm

 

 

 

Hydrocarbon feedstocks,

ethylene, propylene, butadiene

GPR-18 MS

GPR-17 MS

GPR-17 MS-W

GPR-18

GPR-17

GPR-17 W

 

 

- Spot checking above

 

GPR-1200 MS

GPR-1200

GPR-1100

 

 

 

 

ppm level O2 contamination of pipelines containing natural gas and olefin feedstocks assures quality of polyolefin product; and, increasing O2 levels indicate an air leak creating a potentially explosive hazard

<5 ppm O2

 

Ethylene, propylene, butadiene

GPR-18

GPR-17

GPR-17 W

GPR-1500 AIS

GPR-1500 (barriers)

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Low ppm level O2 contamination of Zieglar-Natta and metallocene catalysts used to initiate and control the polymerization reaction to assure product quality and processing performance of plastics such as polyethylene, polypropylene, polyesters, etc.

50 ppb to 10 ppm O2

 

 

 

Ethylene, propylene, butadiene, N2 blanket

GPR-18 MS

GPR-17 MS

GPR-18

GPR-17

GPR-17 W

 

 

 

- Spot checking above

 

GPR-1200

GPR-1100

ppm level N2 for inert blanking of chemicals and refined feedstocks during storage and/or transport by barge, rail, truck tanker or pipeline

0-10 ppm O2

 

N2

GPR-18

GPR-17

GPR-17 W

GPR-1500 AIS

GPR-1500 (barriers)

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

ppm level N2 for inert blanking of hydrocarbon processing or storage on offshore platform

0-10 ppm O2

 

N2

GPR-18

GPR-17

GPR-17 W

GPR-1500 AIS

GPR-1500 (barriers)

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

O2 impurity in hydrogen mixed with air to produce hydrogen peroxide (H2O2)

0-10 ppm O2

Air

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

O2 impurity in production of sodium benzoate a food preservative

0-10% O2

 

Air

GPR-28

GPR-27

GPR-27 W

 

- Spot checking above

 

GPR-2000

GPR-2000 P

 

 

 

 

High purity O2 generated cyrogenically used in conjunction with newly developed closed loop processes enable producers of intermediate products to switch from olefin feedstocks to less expensive alkane feedstocks (butane, ethane and propane), recirculate offgases and smaller vessel size (additional cost savings) while reducing the potential for explosive hazards. Products:

- acrylonitrile (propane in lieu of propylene)

- ethylene oxide & ethylene dichloride

- vinyl acetate monomer

- caprolactam

- maleic anhydride

100% O2

 

Varies

GPR-3100

GPR-3100 W

GPR-2500 MO

 

- Spot checking above

 

GPR-35 MO

Pure O2 generated cryogenically, pressure swing adsorption (PSA) and vacuum pressure swing adsorption (VPSA) processes mounted on skids replaces air to enrich existing processes and boost product yield and reduce NOx emissions:

- fluid catalytic cracking

- sulfur recovery (reduce content in vehicle

  fuels and use heavier crude feedstocks

  without being constrained by the capacity

  of the sulfur plant)

- sulfuric acid regeneration (used in the

  production of titanium dioxide)

- aluminum smelters

- glass smelters

30% to 100% O2

 

 

Varies

GPR-3100

GPR-3100 W

GPR-2500 MO

GPR-2600

GPR-2600 W

GPR-2500

GPR-2900

 

 

- Spot checking above

 

GPR-35 MO

GPR-2000

GPR-2000 P

 
Application Guide - Semiconductor
 Service
 Measurement
 Gas Stream
 Analyzer Options

Ultra High Purity N2 for heat treating silicon wafers

0.25 ppb to 10 ppb O2

N2, H2, Ar

GPR-1600 UHP

GPR-1600 UHP-B

Contamination of N2, H2, Ar carrier gases

0.25 ppb to 10 ppb O2

N2, H2, Ar

GPR-1600 UHP

GPR-1600 UHP-B

Contamination of H2 scavenger gases used in atmosphere soldering and annealing copper films.

0.25 ppb to 10 ppb O2

N2, H2, Ar

GPR-1600 UHP

GPR-1600 UHP-B

Non-invasive leak detection in UHP gas distribution systems with mobile cart

Spot check

N2, H2, Ar

GPR-1600 UHP

GPR-1600 UHP-B

ppm purity cryogenic, ceramic membrane, pressure swing adsorption (PSA) skid and deoxo catalytic generated N2 (5 nines) for wafer oxidation furnaces

0-10 ppm O2

 

N2, H2

GPR-1600 UHP

GPR-1600 UHP-B

GPR-1600 MS

GPR-1600 MS-W

 

- Spot checking above

 

GPR-1200 MS

O2 deficiency in confined areas

<19.5-20.0% O2

Air, N2

GPR-35

Application Guide - Steel
 Service
 Measurement
 Gas Stream
 Analyzer Options

Low ppm purity H2 for heat treating and annealing processes producing desired hardness and brightness

0-10 ppm O2

 

H2, N2

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

 

 

 

 

Membrane air separator N2 skids

0.1% to 5% O2

Air

GPR-2500

GPR-29

 
Application Guide - Shipping
 Service
 Measurement
 Gas Stream
 Analyzer Options

ppm level N2 for inert blanking of refined feedstocks and other hydrocarbon cargo during transport

0-10 ppm O2

Spot checking

N2

GPR-1600

GPR-1600 W

GPR-1500

 

- Spot checking above

 

GPR-1200

GPR-1100

Application Guide - Welding
 Service
 Measurement
 Gas Stream
 Analyzer